The insulation piercing clamp is mainly composed of a reinforcing shell, a puncture blade, a gasket, a waterproof silicone grease, a high-strength bolt, a torque nut and a cable end cap. When the cable needs to be branched or connected, the cable branch line terminal is inserted into the waterproof terminal. Cap sleeve, after determining the branch position of the main line, use a socket wrench to tighten the torque nut on the clamp. During the process, the contact blade will pierce the cable insulation and contact the conductor. The gasket ring is around the piercing position. The grease leaks. When the torque reaches the set value, the nut torque mechanism comes off, the main line and the branch line are turned on, and the waterproof performance and electrical effect reach the parameters required by the standard.
Type |
Equivalent Type |
Main Line Section |
Branch Section |
Norminal Current |
Dimensions |
Weight (g) |
Piercing Depth (mm) |
Bolt |
SL756 |
JJC888 |
0.75-6 |
0.75-6 |
41 |
21x27x23 |
10 |
1-1.5 |
1 |
SL101 |
JJC-1 |
1.5-25 |
1.5-10 |
55 |
27x41x62 |
55 |
1.5-2 |
1 |
SLEP |
JJC-2 |
16-95 |
1.5-10 |
55 |
27x41x62 |
55 |
1-2 |
1 |
SL102 |
JJC-3(A) |
6-50 |
4-25 |
157 |
42x45x62 |
110 |
2.5-3.5 |
1 |
SL2-95 |
JJC-3 |
16-95 |
4-35(50) |
157 |
46x52x87 |
160 |
2.5-3.5 |
1 |
SL2-150 |
JJC-4 |
50-150 |
6-35(50) |
157 |
46x52x87 |
162 |
2.5-3.5 |
1 |
SL3-95 |
JJC-5 |
25-95 |
25-95 |
214 |
50x61x100 |
198 |
3-4 |
1 |
SL3-120 |
JJC-5-1 |
16-120 |
16-120 |
214 |
50x61x100 |
198 |
3-4 |
1 |
SL4-150 |
JJC-6 |
(35)50-150 |
(35)50-150 |
316 |
50x61x100 |
280 |
3-4 |
1 |
SL6 |
JJC-7 |
120-240 |
25-120 |
276 |
52x68x100 |
360 |
3-4 |
1 |
SL7 |
JJC-7-1 |
150-240 |
10-25 |
102 |
52x68x100 |
336 |
3-4 |
1 |
SL240 |
JJC-8 |
95-240 |
95-240 |
425 |
83x130x130 |
1020 |
4-5 |
2 |
SL300 |
300 |
25-95 |
425 |
83x130x130 |
1040 |
4.5-5.5 |
2 |
|
95-240 | ||||||||
SL400 |
400 |
25-95 |
425 |
83x130x130 |
1040 |
5-6 |
2 |
|
95-240 |
Installation of twin-screw insulated puncture clamp
1.Unscrew the clamp and insert the main wire into the main slot.Do not jam the main line and the tool holder.Note whether the wire diameter range corresponds to this clamp.
2.Place the branch line in the branch line slot.Note the same as above.
3.Tighten with a socket wrench.Disable the open end wrench.
4.Note that the two nuts should be screwed down in sequence.
5.When tightening to a certain strength, the constant torque nut is broken and the installation is completed.
Certificate
Product showroom
http://www.sentuoelectric.com/